ESME_RINVDSTADR in SMPP
What is ESME_RINVDSTADR?
ESME_RINVDSTADR (Error Code: 0x0000000B) is an SMPP error indicating that the destination address provided in the request is invalid or not allowed by the SMSC.
Possible Causes
- The
destination_addr
field is empty or incorrectly formatted. - The destination number is longer or shorter than the allowed length.
- The destination number contains invalid characters (e.g., letters or special symbols).
- The
dest_addr_ton
anddest_addr_npi
values are incorrect or not supported. - The destination number is blocked or not routable by the SMSC.
When Does It Happen?
This error occurs when submitting an SMPP PDU (such as submit_sm
) with an invalid or unsupported destination address.
Example SMPP PDU Transaction
Incorrect submit_sm
PDU (Invalid Destination Address)
0000002C (Length) 00000004 (Command ID for submit_sm) 00000000 (Command Status) 00000002 (Sequence Number) 00000000 (Service Type) 05 (Source Address TON - Alphanumeric) 00 (Source Address NPI - Unknown) 74657374 000000 (Source Address: "test") 01 (Destination Address TON - International) 01 (Destination Address NPI - ISDN) 00000000 (Empty Destination Address) 00 (Priority Flag) 01 (Registered Delivery Flag) 00000000 (Message Length) 48656C6C6F (Message: "Hello")
Response PDU (submit_sm_resp
) with ESME_RINVDSTADR
00000010 (Length) 80000004 (Command ID for submit_sm_resp) 0000000B (Command Status - ESME_RINVDSTADR) 00000002 (Sequence Number)
Issue: The destination_addr
field is empty, causing the SMSC to reject the request.
How to Solve It?
- Ensure that the
destination_addr
field contains a valid phone number. - Use a valid
dest_addr_ton
anddest_addr_npi
: - For international numbers:
dest_addr_ton = 1
,dest_addr_npi = 1
- For national numbers:
dest_addr_ton = 2
,dest_addr_npi = 1
- Verify that the destination number is within the supported length and format.
- Ensure that the number is not blocked or restricted by the SMSC.
- Enable debugging logs to inspect the exact value being sent in the PDU.
If the issue persists, contact the SMSC provider to confirm routing rules for the destination number.