What is ESME_RINVSYSID?
ESME_RINVSYSID (Error Code: 0x0000000F) is an SMPP error indicating that the system_id provided in the bind request is invalid or unrecognized by the SMSC.
Possible Causes
- The
system_idfield in the bind request is incorrect. - The provided
system_iddoes not exist in the SMSC's database. - The ESME account associated with the
system_idhas been disabled or suspended. - The
system_idcontains unsupported characters or formatting errors. - There is a typo or mismatch in the
system_idcompared to the SMSC's records.
When Does It Happen?
This error occurs when sending a bind_transmitter, bind_receiver, or bind_transceiver PDU with an invalid system_id.
Example SMPP PDU Transaction
Incorrect bind_transmitter PDU (Invalid System ID)
0000001F (Length) 00000002 (Command ID for bind_transmitter) 00000000 (Command Status) 00000001 (Sequence Number) 696E7661 6C696400 (System ID: "invalid") ; Incorrect system ID 70617373 776F726400 (Password: "password") 534D5050 0000 (System Type: "SMPP") 34 (Interface Version) 00 (Address TON) 00 (Address NPI) 00 (Address Range)
Response PDU (bind_transmitter_resp) with ESME_RINVSYSID
00000010 (Length) 80000002 (Command ID for bind_transmitter_resp) 0000000F (Command Status - ESME_RINVSYSID) 00000001 (Sequence Number)
Issue: The system_id provided ("invalid") is not recognized by the SMSC.
How to Solve It?
- Ensure that the correct
system_idis being used. - Verify that the
system_idmatches what is registered with the SMSC. - Check for typos, extra spaces, or incorrect encoding in the
system_idfield. - Confirm that the account associated with the
system_idis active and not suspended. - Enable debugging logs to inspect the exact values being sent in the PDU.
If the issue persists, contact the SMSC provider to verify the validity of the system_id and resolve authentication issues.