ESME_RINVSYSTYP in SMPP

What is ESME_RINVSYSTYP?

ESME_RINVSYSTYP (Error Code: 0x00000053) is an SMPP error indicating that the system_type provided in the bind_transmitter, bind_receiver, or bind_transceiver PDU is invalid or not recognized by the SMSC.

Possible Causes

  • The system_type field contains an incorrect or unsupported value.
  • The SMSC does not recognize the specified system_type.
  • The ESME is attempting to bind with an invalid or empty system_type.

When Does It Happen?

This error occurs when an ESME sends a bind_transmitter, bind_receiver, or bind_transceiver request with an invalid system_type value.

Example SMPP PDU Transaction

Incorrect bind_transmitter PDU (Invalid System Type)

0000001B (Length)
00000002 (Command ID for bind_transmitter)
00000000 (Command Status)
00000001 (Sequence Number)
74657374 00 (System ID: "test")
70617373 00 (Password: "pass")
696E7661 6C6964 00 (Invalid System Type: "invalid")
34 (Interface Version: 3.4)
00 (Address TON)
00 (Address NPI)
00 (Address Range)

Response PDU (bind_transmitter_resp) with ESME_RINVSYSTYP

00000010 (Length)
80000002 (Command ID for bind_transmitter_resp)
00000053 (Command Status - ESME_RINVSYSTYP)
00000001 (Sequence Number)

Issue: The system_type field contains an invalid value ("invalid"), which is not recognized by the SMSC.

How to Solve It?

  • Use a valid system_type as per the SMSC configuration.
  • Some SMSCs require a specific system_type, while others may allow an empty value.
  • Confirm with the SMSC provider what values are accepted for system_type.
  • Ensure that the bind request is correctly formatted before sending.

If the issue persists, check the SMPP logs, correct the PDU values, and consult the SMSC provider for further troubleshooting.